Micronics U1000MKII HM Technical Datasheet.pdf
Technical Datasheet
Micronics Ultra fl o
U 1000 MKII - HM Clamp - on
Meter
The U 1000 MKII HM is an ultrasonic clamp on thermal heat and energy meter that uses
ultrasound to measure fl ow rate and PT 100 temperature sensors to measure fl ow and return
temperatures . It displays energy rate and totalised energy with pulse output and
communication options , so it can be a standalone meter or part of an aMT or BEMS system .
It is simple to install : connect power , enter the pipe inside diameter , adjust the sensors and
clamp on the pipe , with no specialist skills or tools needed .
Features :
Clamp on , no pipe cutting
Ultrasonic transit time fl ow
measurement
Pulse or frequency output , optional
MBus
Pipe range 22 to 180 mm outside
diameter
Hot water , chilled water and chilled
water with glycol
Complies with EN 1434 section 6 heat
calculation
Made in Britain
Managed
Services
Meter Data
Management
Billing Solutions
PAYG
Management
Online Account
Management
sycous . com
sycous . com +44 (0) 113 3604 776 info @ sycous . com New York House , 1 Harper Street , Leeds , LS 2 7 EA
Sycous Limited is Registered in England and Wales . Company Number 08836039
Technical Datasheet
Micronics Ultra fl o U 1000 MKII - HM Clamp - on Meter
Part Codes
MI 100 HM Sycous WR 1000 Clamp on Heat Meter , A Transducers , 22 to 115
mm , Pulse and MBus
MI 101 HM Sycous WR 1000 Clamp on Heat Meter , B Transducers , 125 to 180
mm , Pulse and MBus
MI 200 HM Sycous WR 1000 MKII Wall Mounted Clamp on Heat Meter , A
Transducers , 22 to 115 mm , Pulse and MBus
MI 201 HM Sycous WR 1000 MKII Wall Mounted Clamp on Heat Meter , B
Transducers , 125 to 180 mm , Pulse and MBus
SY 912 CO Clamp On Meter Site Visit and Survey
Technical Speci fi cation
Measurement
Technique Ultrasonic transit time for fl ow , PT 100 Class B 4 wire for
temperature
Turn down ratio 200:1
Accuracy Plus or minus 1 to 3 % of fl ow reading above 0.3 m / s
Flow velocity range 0.1 to 10 m / s
Pipe range 22 to 115 mm or 125 to 180 mm outside diameter ( depends on pipe
material and internal diameter )
Water temperature range 0 to 85 ° C
Temperature sensors Clamp on PT 100 Class B 4 wire , 0 to 85 ° C , resolution 0.1 ° C ,
minimum delta T 0.3 ° C
Outputs
Output
Pulse or frequency . Pulse for volume fl ow and energy in kWh ,
frequency for fl ow rate . Pulse output can be set as a loss of signal
or low fl ow alarm
Communication Optional MBus
Electrical and mechanical
External power supply 12 to 24 V , plus or minus 10 %, AC or DC , 7 W per unit . Optional
plug in 12 V power supply
Electronics enclosure IP 54
Input and output cable 5 m x 6 core for power in and pulse out
Dimensions 250 x 48 x 90 mm ( electronics and guide rail )
Pipe materials Steel , stainless steel , plastic and copper
Managed
Services
Meter Data
Management
Billing Solutions
PAYG
Management
Online Account
Management
sycous . com
sycous . com +44 (0) 113 3604 776 info @ sycous . com New York House , 1 Harper Street , Leeds , LS 2 7 EA
Sycous Limited is Registered in England and Wales . Company Number 08836039