BMeter Hydroclima 2 User Manual.pdf
HYDROCLIMA 2 USER MANUAL
50000004
B METERS
HYDROCLIMA 2 - User Manual
Contents
Preface 2
Safety and warranty 1
Important information i
Intended use of the product i
Lithium batteries safety guidelines p
Precautions for lithium batteries |
General information 2
Packaging content 2
Installation and connection 3
Installation 3
Exterior temperature sensor installation (EXT version) 4
Display 5
Button 8
Alarms 8
Configuration 9
Technical data 9
Dimensions and drawings 10
Contacts Ke
HYDROCLIMA 2 - User Manu
Preface
This User's manual comprises rules, information and advices regarding proper use of the heat cost allocator HC2
manufactured by B METERS Company. Please, read this manual before using the product. It shall enable a proper and
safe operation of the product.
Failure to meet recommendations and guidelines set out in the document may result in improper measurements and
it constitutes basis to refuse potential complaints.
Safety and warranty
Important information
The product must be installed professionally, in accordance with defined guidelines regarding the installation process;
the installation may be carried out by qualified and trained personnel only!
Intended use of the product
The heat cost allocator is intended to directly measure quantity of consumed thermal energy emitted by a radiator.
Each use other than the described above and any modifications to the device shall be considered an improper use.
The device is designed to measure central heating systems, with vertical distribution of a heating agent. On the
grounds of units measured by the heat cost allocator and/or the ambient temperature, clearing of building heating
costs is taking place.
Lithium batteries safety guidelines
Set of the heat cost allocator comprises a lithium battery as well. This type of the battery is considered to be
dangerous.
Always observe the binding transport and storage regulations!
Precautions for lithium batteries
— keep batteries in a dry room
—- do not heat up a battery up to temperatures exceeding 110°C and do not throw it into a fire
— do not cause a short circuit
— donot open and do not damage a battery
—- do not charge the battery
— store in places out of the reach of children
9 1
HYDROCLIMA 2 - User Manua
General information
Hydroclima 2 is a two sensor, electric, second generation heat cost allocator. It is intended to measure directly
consumed thermal energy emitted by a radiator.
The heat cost allocator provides non-dimensional units of the thermal energy consumption depending on a
temperature of a radiator and a temperature of a room. It also provides an opportunity to record historical data
of heat consumption,temperatures and other statistics. Based on the configuration all the data can be sent via
Wireless MBus.
Every heat cost allocator uses a specific algorithm to count the consumption units. Only devices of the same
manufacturer and model can be installed in the same unit of cost.
Packaging content
— aheat cost allocator Hydroclima 2
— analuminum heat sink
— aprotective seal for the heat cost allocator
Additional elements:
- installation manual*
—- aleaflet for a final user*
—- fixing elements **
* available on website or on request
**if ordered with the heat cost allocator
2 8
HYDROCLIMA 2 - User Manu:
Installation and connection
Installation
An Heat cost allocator can be install at radiator in two steps.
Firstly, an aluminum heat sink is fixed to a radiator. Depending on type of a radiator and dedicated installation
technology, the following methods are applied: fixing elements, welding or gluing. Then, place the heat cost
allocator on a fixed heat sink and close it, using the seal from the bottom.
Detailed guidelines regarding installation methods on particular radiators are indicated in the document
“Installation Manual”.
2 |
J]
9 3
HYDROCLIMA 2 - User Manual
Exterior temperature sensor installation (EXT version)
The external temperature sensor (separate component) has to be connected before heat cost allocator is installed.
This operation consists of three steps:
1. First of all, upper edge of the temperature sensor has to be placed in the socket to tilt plastic hook
A |
2. Next, gently push the lower edge (from the wire side) of the sensor
Ve, 3 | CLICK!
SSS SS
7 £5)
3. Last step is to place and fit the wire in the dedicated slot
lanu
Display
To present the data, a digital display with icons is available. A full lines test of the display is presented below:
Err Open EXT 2}
The heat cost allocator shows data in two modes, a basic mode and an extended one:
— Basic mode takes place by short-time pushing of the button (not exceeding 2 sec.);
— Extended mode takes place by pushing of the button exceeding 3 sec.
Basic mode - data is displayed as a loop repeated three times.
The following table represents a cycle of displaying information on recorded data and errors.
Item Conditionally Message Timeins Description
1 Hoa 3 Present data
2 Ux 3 Data (results) for a terminated clearing period
3 “8” 3 Average ambient temp. for a terminated period
Total 9
Extended mode - can be entered exclusively during an active basic mode. Three cycles of the expanded loop are
displayed and subsequently the device goes back in stand-by mode.
Item Conditionally Message Timeins Error
1: (ol 2 Present data
2 glia 2 Data (results) for a terminated clearing period
3 «3 2 Average ambient temp. for a present period
4 “By” 2 Average ambient temp. for a terminated period
5 “IP” 2 The first adjustment coefficient (KC)
6 “2P" 2 The second adjustment coefficient (KQ)
7 iy 2 Beginning date of a clearing period
8 27 2 Closing date of a clearing period
9 “H” 2 Control code
10 2 Serial number (last 6 digits)
Total 20
HYDROCLIMA 2 - User Manual
In case of recording of the following events, additional results are displayed, whether or not the display has been
initiated to present the data:
— A heat cost allocator with data presentation switched off (data presentation in a loop, with messages displayed
one by one)
Collective information on a group of errors / events
3 vs wo Operation time exceeded - battery is empty
— The heat cost allocator initiated to display in a basic mode or in an extended mode (continuous presentation all the
time of the basic mode):
Collective information on a group of errors / incidents
Additionally, the following special data presentation cycles are possible:
—- Factory's settings (no configuration)
— Stand-by mode - information displayed between the configuration to the start of the accounting
— Seal application
6 8
lanu
Examples of indications:
8 i BAA Display test - all segments on ¢ ] 0 - Closing date of a clearing period
Err Open EXT ©
| Display test - all segments of f b | Be J Control code
| uJ Present consumption [C] J | Serial number last 6 digits
1" r
[1] 9 q 0¢ nr L f c | n Collective information on a group
P! Em on a present consumption
C c n : Average ambient temp. for a The first adjustment coefficient
[] Ul present period (KC)
Information that the heat cost
v | Average ambient temp. for a ( | fn allocator operates with
8 | A terminated period IJ an external sensor and present
EXT consumption
0D present consumptions
i n ny Opening date of a clearing period { L } g - Seal application
viv
{ Mn Opening of the seal and informa- (lnk
| J tion on present consumption have Configuration received
Open been recorded
q [ - t p Stand-by mode r F Radio frequency mode
HYDROCLIMA 2 - User Manua
Button
The timing of button pressure corresponds to the following events:
— Non-configured heat cost allocator (factory settings); Pressing the button for the first time prepares the device to
receive the configuration data. After a successful configuration the “CONF” information appears in the display.
—- Previously configured heat cost allocator (normal operation mode):
- Pushing of the button not longer than 2 seconds - initiation of the display basic data described in the previous
chapter
—- Pushing of the button longer than 3 seconds - initiation of the display extended data described in the previous
chapter
- Pushing of the button longer than 5 seconds - the allocator activate rf transmitting mode that allow the
communication with software in two modes:
~ Change of the operation configuration. Successful configuration is confirmed by “CONF” information
displayed in the display for 10 s. In case the configuration is not successful, it is necessary to release the
button and push it again
~ Sending of the following extended data:
-apack including history of units memorized at the end of 24 previously months
+ apack including a history of average temperatures for recent 24 months
- apack comprising all data stored in the memory of the heat cost allocator
Alarms
In the status field we have an error/event report. Possible errors / events are listed in the table.
C15 Power failure has been recorded. Power supply has been temporarily lost, all data has been restored from non-volatile memory.
C13 A quartz oscillator malfunction event has been recorded. Flag deleted automatically after date and time update.
cnn The overflow of the heat consumption indication parameter [C] was recorded. Closing the billing period does not clear this flag,
therefore the overflow event may also relate to the past period.
c10 Reduced temperature was recorded for a longer period (radiator temperature parameter TK). The value of the TK radiator
temperature parameter below 16 °C was registered for a period longer than 24h.
co Exceeding the range of permissible temperature values (radiator temperature parameter TK).
Permitted temperature range is: <5 °C... 95 °C>
88 An open case event was recorded, the date of first occurrence is recorded. Clearing this flag also resets the date of occurrence. The
flag can be cleared automatically in the event of the first seal application after the configuration process.
Al State of verification of the opening sensor and button. The flag is cleared automatically after closing the cover and pressing the
button.
AC Default configuration parameter values. Device not configured or data from non-volatile memory lost; flag cleared automatically
after the configuration process.
8 y
HYDR LIMA 2 J Me IE
Configuration
Programming and configuration of the device is carried out by radio, using an RFM-RX2 and BMetering software.
To trigger the configuration procedure, the BMetering software must be properly configured:
— For the factory state of the allocator, press the button for < 1s,
— For the allocator already configured, press the button for > 5s, until the display shows the message “rf”.
The method of configuration has been described in the documentation concerning the B Metering software
user manual
Technical data
Type Hydroclima 2, electronic, two-sensor one
Available versions Compact, with an external temperature probe
LCD 7 segment display with icons
Dimensions 102 mm x 40 mm x 27 mm (hx w x d)
Power supply Lithium battery 3.6V
Maximum battery life 10 Years*
From 35°C to 105°C
Application temperatures From 35°C to 130°C (version with a remote sensor, length of the sensor
3m)
Accuracy of the measurement Temperature Sensors — thermistors 1%
i Physical (display)
Communication with the device Radio, two-ways directions
Configuration Radio configuration, via Bmetering software and RFM-RX2
Power of the transmitter 10 dBm (10 Mw)
Frequency of the transmitter 868,950 Mhz
Frequency of the receiver 868,300 Mhz
Radiator’s temperature >22.5°C
Start accounting ( thermal energy consumption units) At 23k (difference between a temp. Of a radiator and the ambient
temp.)
Measurement method Two-sensor or single sensor (depending of the conditions)
* The battery life strongly depends on the working time window, set during the configuration process, and on the
environmental conditions. Estimation of the battery life is given by the configuration software.
hl 9
Dimensions and drawings
(
|
|
10 ®
YDROCLIMA 2 - User Manus
Contacts
B METERS srl
Via Friuli, 3 « Gonars 33050 (UD) « ITALY
Tel: +39 0432 931415
Tel: +39 0432 1690412
Fax: +39 0432 992661
E-mail (sales/info): info@bmeters.com
E-mail (support): ticket@bmeters.com
Web: www.bmeters.cor
12 9
HYDROCLIMA 2 USER MANUAL
50000004
B METERS
HYDROCLIMA 2 - User Manual
Contents
Preface 2
Safety and warranty 1
Important information i
Intended use of the product i
Lithium batteries safety guidelines
Precautions for lithium batteries
General information 2
Packaging content 2
Installation and connection 3
Installation 3
Exterior temperature sensor installation (EXT version) 4
Display 5
Button 8
Alarms 8
Configuration 9
Technical data 9
Dimensions and drawings 10
Contacts
HYDROCLIMA 2 - User Manu
Preface
This manual comprises rules, information and advices regarding proper use of the heat cost allocator HC2
manufactured by B METERS Company. Please, read this manual before using the product. It shall enable a proper and
safe operation of the product.
Failure to meet recommendations and guidelines set out in the document may result in improper measurements and
it constitutes basis to refuse potential complaints.
Safety and warranty
Important information
The product must be installed professionally, in accordance with defined guidelines regarding the installation process;
the installation may be carried out by qualified and trained personnel only!
Intended use of the product
The heat cost allocator is intended to directly measure quantity of consumed thermal energy emitted by a radiator.
Each use other than the described above and any modifications to the device shall be considered an improper use.
The device is designed to measure central heating systems, with vertical distribution of a heating agent. On the
grounds of units measured by the heat cost allocator and/or the ambient temperature, clearing of building heating
costs is taking place.
Lithium batteries safety guidelines
Set of the heat cost allocator comprises a lithium battery as well. This type of the battery is considered to be
dangerous.
Always observe the binding transport and storage regulations!
Precautions for lithium batteries
keep batteries in a dry room
do not heat up a battery up to temperatures exceeding 110°C and do not throw it into a fire
do not cause a short circuit
donot open and do not damage a battery
do not charge the battery
store in places out of the reach of children
1
HYDROCLIMA 2
- User Manua
General information
Hydroclima 2 is a two sensor, electric, second generation heat cost allocator. It is intended to measure directly
consumed thermal energy emitted by a radiator.
The heat cost allocator provides non-dimensional units of the thermal energy consumption depending on a
temperature of a radiator and a temperature of a room. It also provides an opportunity to record historical data
of heat consumption,temperatures and other statistics. Based on the configuration all the data can be sent via
Wireless M-Bus.
Every heat cost allocator uses a specific algorithm to count the consumption units. Only devices of the same
manufacturer and model can be installed in the same unit of cost.
Packaging content
aheat cost allocator Hydroclima 2
analuminum heat sink
aprotective seal for the heat cost allocator
Additional elements:
- installation manual*
- aleaflet for a final user*
- fixing elements **
* available on website or on request
**if ordered with the heat cost allocator
2 8
HYDROCLIMA 2 - User Manu:
Installation and connection
Installation
An Heat cost allocator can be install at radiator in two steps.
Firstly, an aluminum heat sink is fixed to a radiator. Depending on type of a radiator and dedicated installation
technology, the following methods are applied: fixing elements, welding or gluing. Then, place the heat cost
allocator on a fixed heat sink and close it, using the seal from the bottom.
Detailed guidelines regarding installation methods on particular radiators are indicated in the document
"Installation Manual".
2
|
J]
3
HYDROCLIMA 2 - User Manual
Exterior temperature sensor installation (EXT version)
The external temperature sensor (separate component) has to be connected before heat cost allocator is installed.
This operation consists of three steps:
1. First of all, upper edge of the temperature sensor has to be placed in the socket to tilt plastic hook
A |
2. Next, gently push the lower edge (from the wire side) of the sensor
Ve, 3
|
SSS
SS 7 £5)
3. Last step is to place and fit the wire in the dedicated slot
lanu
Display
To present the data, a digital display with icons is available. A full lines test of the display is presented below:
Err Open EXT
The heat cost allocator shows data in two modes, a basic mode and an extended one:
Basic mode takes place by short-time pushing of the button (not exceeding 2 sec.);
Extended mode takes place by pushing of the button exceeding 3 sec.
Basic mode - data is displayed as a loop repeated three times.
The following table represents a cycle of displaying information on recorded data and errors.
Item Conditionally Message Timeins Description
1 Hoa 3 Present data
2 3 Data (results) for a terminated clearing period
3 3 Average ambient temp. for a terminated period
Total 9
Extended mode - can be entered exclusively during an active basic mode. Three cycles of the expanded loop are
displayed and subsequently the device goes back in stand-by mode.
Item Conditionally Message Timeins Error
1: 2 Present data
2 2 Data (results) for a terminated clearing period
3 2 Average ambient temp. for a present period
4 2 Average ambient temp. for a terminated period
5 "IP" 2 The first adjustment coefficient (KC)
6 "2P" 2 The second adjustment coefficient (KQ)
7 iy 2 Beginning date of a clearing period
8 27 2 Closing date of a clearing period
9 "H" 2 Control code
10 2 Serial number (last 6 digits)
Total 20
HYDROCLIMA 2 - User Manual
In case of recording of the following events, additional results are displayed, whether or not the display has been
initiated to present the data:
cost allocator with data presentation switched off (data presentation in a loop, with messages displayed
one by one)
Collective information on a group of errors / events
vs wo Operation time exceeded -
battery is empty
The heat cost allocator initiated to display in a basic mode or in an extended mode (continuous presentation all the
time of the basic mode):
Collective information on a group of errors / incidents
Additionally, the following special data presentation cycles are possible:
settings (no configuration)
Stand-by mode - information displayed between the configuration to the start of the accounting
Seal application
6 8
lanu
Examples of indications:
8 BAA Display test - all segments on ¢ 0 Closing date of a clearing period
Err Open EXT ©
Display test - all segments of f b | J Control code
| Present consumption [C] J | Serial number last 6 digits
1" r
[1] 9 q 0¢ L | n Collective information on a group
Em on a present consumption
c n Average ambient temp. for a The first adjustment coefficient
[] present period (KC)
Information that the heat cost
| Average ambient temp. for a | fn allocator operates with
| A
terminated period IJ an external sensor and present
EXT consumption
0D present consumptions
i n Opening date of a clearing period { L - Seal application
viv
{ Mn Opening of the seal and informa-
| tion on present consumption have Configuration received
Open been recorded
- p Stand-by mode r F Radio frequency mode
HYDROCLIMA 2
- User Manua
Button
The timing of button pressure corresponds to the following events:
Non-configured heat cost allocator (factory settings); Pressing the button for the first time prepares the device to
receive the configuration data. After a successful configuration the "CONF" information appears in the display.
Previously configured heat cost allocator (normal operation mode):
- Pushing of the button not longer than 2 seconds - initiation of the display basic data described in the previous
chapter
- Pushing of the button longer than 3 seconds - initiation of the display extended data described in the previous
chapter
- Pushing of the button longer than 5 seconds - the allocator activate rf transmitting mode that allow the
communication with software in two modes:
~ Change of the operation configuration. Successful configuration is confirmed by "CONF" information
displayed in the display for 10 s. In case the configuration is not successful, it is necessary to release the
button and push it again
~ Sending of the following extended data:
-apack including history of units memorized at the end of 24 previously months
including a history of average temperatures for recent 24 months
comprising all data stored in the memory of the heat cost allocator
Alarms
In the status field we have an error/event report. Possible errors / events are listed in the table.
C15 Power failure has been recorded. Power supply has been temporarily lost, all data has been restored from non-volatile memory.
A quartz oscillator malfunction event has been recorded. Flag deleted automatically after date and time update.
The overflow of the heat consumption indication parameter [C] was recorded. Closing the billing period does not clear this flag,
therefore the overflow event may also relate to the past period.
c10 Reduced temperature was recorded for a longer period (radiator temperature parameter TK). The value of the TK radiator
temperature parameter below 16 °C was registered for a period longer than 24h.
co Exceeding the range of permissible temperature values (radiator temperature parameter TK).
Permitted temperature range is: <5 °C... 95 °C>
88 An open case event was recorded, the date of first occurrence is recorded. Clearing this flag also resets the date of occurrence. The
flag can be cleared automatically in the event of the first seal application after the configuration process.
Al State of verification of the opening sensor and button. The flag is cleared automatically after closing the cover and pressing the
button.
Default configuration parameter values. Device not configured or data from non-volatile memory lost; flag cleared automatically
after the configuration process.
8
HYDR LIMA 2 J Me IE
Configuration
Programming and configuration of the device is carried out by radio, using an RFM-RX2 and BMetering software.
To trigger the configuration procedure, the BMetering software must be properly configured:
For the factory state of the allocator, press the button for < 1s,
For the allocator already configured, press the button for > 5s, until the display shows the message "rf".
The method of configuration has been described in the documentation concerning the B Metering software
user manual
Technical data
Type Hydroclima 2, electronic, two-sensor one
Available versions Compact, with an external temperature probe
LCD 7 segment display with icons
Dimensions 102 mm x 40 mm x 27 mm (hx w x d)
Power supply Lithium battery 3.6V
Maximum battery life 10 Years*
From 35°C to 105°C
Application temperatures From 35°C to 130°C (version with a remote sensor, length of the sensor
3m)
Accuracy of the measurement Temperature Sensors thermistors 1%
Physical (display)
Communication with the device Radio, two-ways directions
Configuration Radio configuration, via Bmetering software and RFM-RX2
Power of the transmitter 10 dBm (10 Mw)
Frequency of the transmitter 868,950 Mhz
Frequency of the receiver 868,300 Mhz
Radiator's temperature >22.5°C
Start accounting ( thermal energy consumption units) At 23k (difference between a temp. Of a radiator and the ambient
temp.)
Measurement method Two-sensor or single sensor (depending of the conditions)
* The battery life strongly depends on the working time window, set during the configuration process, and on the
environmental conditions. Estimation of the battery life is given by the configuration software.
hl 9
Dimensions and drawings
(
|
|
10
2 - User Manus
Contacts
B METERS srl
Via Friuli, 3 Gonars 33050 (UD) « ITALY
Tel: +39 0432 931415
Tel: +39 0432 1690412
Fax: +39 0432 992661
E-mail (sales/info):
E-mail (support): ticket@bmeters.com
Web: www.bmeters.cor
12
v 1.1
II HYDROCLIMA 2 - User Manual
Contents
Preface 1
Safety and warranty 1
Important information 1
Intended use of the product 1
Lithium batteries safety guidelines 1
Precautions for lithium batteries 1
General information 2
Packaging content 2
Installation and connection 3
Installation 3
Exterior temperature sensor installation (EXT version) 4
Display 5
Button 8
Alarms 8
Configuration 9
Technical data 9
Dimensions and drawings 10
Contacts 11
1 HYDROCLIMA 2 - User Manual
Preface
Safety and warranty
Important information
Intended use of the product
Lithium batteries safety guidelines
Precautions for lithium batteries
Always observe the binding transport and storage regulations!
This User’s manual comprises rules, information and advices regarding proper use of the heat cost allocator HC2
manufactured by B METERS Company. Please, read this manual before using the product. It shall enable a proper and
safe operation of the product.
Failure to meet recommendations and guidelines set out in the document may result in improper measurements and
it constitutes basis to refuse potential complaints.
The product must be installed professionally, in accordance with defined guidelines regarding the installation process;
the installation may be carried out by qualified and trained personnel only!
The heat cost allocator is intended to directly measure quantity of consumed thermal energy emitted by a radiator.
Each use other than the described above and any modifications to the device shall be considered an improper use.
→ keep batteries in a dry room
→ do not heat up a battery up to temperatures exceeding 110°C and do not throw it into a fire
→ do not cause a short circuit
→ do not open and do not damage a battery
→ do not charge the battery
→ store in places out of the reach of children
Set of the heat cost allocator comprises a lithium battery as well. This type of the battery is considered to be
dangerous.
The device is designed to measure central heating systems, with vertical distribution of a heating agent. On the
grounds of units measured by the heat cost allocator and/or the ambient temperature, clearing of building heating
costs is taking place.
2 HYDROCLIMA 2 - User Manual
General information
Packaging content
Hydroclima 2 is a two sensor, electric, second generation heat cost allocator. It is intended to measure directly
consumed thermal energy emitted by a radiator.
The heat cost allocator provides non-dimensional units of the thermal energy consumption depending on a
temperature of a radiator and a temperature of a room. It also provides an opportunity to record historical data
of heat consumption,temperatures and other statistics. Based on the configuration all the data can be sent via
Wireless M-Bus.
Every heat cost allocator uses a specific algorithm to count the consumption units. Only devices of the same
manufacturer and model can be installed in the same unit of cost.
Additional elements:
* available on website or on request
** if ordered with the heat cost allocator
→ a heat cost allocator Hydroclima 2
→ an aluminum heat sink
→ a protective seal for the heat cost allocator
→ user’s manual*
→ installation manual*
→ a leaflet for a final user*
→ fixing elements **
3 HYDROCLIMA 2 - User Manual
Installation and connection
Installation
An Heat cost allocator can be install at radiator in two steps.
Firstly, an aluminum heat sink is fixed to a radiator. Depending on type of a radiator and dedicated installation
technology, the following methods are applied: fixing elements, welding or gluing. Then, place the heat cost
allocator on a fixed heat sink and close it, using the seal from the bottom.
Detailed guidelines regarding installation methods on particular radiators are indicated in the document
“Installation Manual”.
4 HYDROCLIMA 2 - User Manual
Exterior temperature sensor installation (EXT version)
The external temperature sensor (separate component) has to be connected before heat cost allocator is installed.
This operation consists of three steps:
1. First of all, upper edge of the temperature sensor has to be placed in the socket to tilt plastic hook
2. Next, gently push the lower edge (from the wire side) of the sensor
3. Last step is to place and fit the wire in the dedicated slot
5 HYDROCLIMA 2 - User Manual
Display
To present the data, a digital display with icons is available. A full lines test of the display is presented below:
The heat cost allocator shows data in two modes, a basic mode and an extended one:
Basic mode - data is displayed as a loop repeated three times.
The following table represents a cycle of displaying information on recorded data and errors.
Extended mode - can be entered exclusively during an active basic mode. Three cycles of the expanded loop are
displayed and subsequently the device goes back in stand-by mode.
→ Basic mode takes place by short-time pushing of the button ( not exceeding 2 sec. );
→ Extended mode takes place by pushing of the button exceeding 3 sec .
Item Conditionally Message Time in s Description
1 “C” 3 Present data
2 “U” 3 Data (results) for a terminated clearing period
3 “ ” 3 Average ambient temp. for a terminated period
Total 9
Item Conditionally Message Time in s Error
1 “C” 2 Present data
2 “U” 2 Data (results) for a terminated clearing period
3 “ ” 2 Average ambient temp. for a present period
4 “ ” 2 Average ambient temp. for a terminated period
5 “IP” 2 The first adjustment coefficient (KC)
6 “2P” 2 The second adjustment coefficient (KQ)
7 “1” 2 Beginning date of a clearing period
8 “2” 2 Closing date of a clearing period
9 “H” 2 Control code
10 2 Serial number (last 6 digits)
Total 20
6 HYDROCLIMA 2 - User Manual
In case of recording of the following events, additional results are displayed, whether or not the display has been
initiated to present the data:
Additionally, the following special data presentation cycles are possible:
Item Conditionally Message Time in s Error
1 YES “Err”
6
Collective information on a group of errors / events
2 YES “Open” Enclosure opening (event)
3 YES “ ” Operation time exceeded - battery is empty
4 14 Switched off display
Total 20
Item Conditionally Message Time in s Error
1 “- - - - -” 2 Factory’s settings (no configuration)
2 6 Switched off display
Total 8
Item Conditionally Message Time in s Error
1 “SLEEP” 2 Stand-by mode
2 6 Switched off display
Total 8
Item Conditionally Message Time in s Error
1 “CLOSE” 10 Seal application
Total 10
Item Conditionally Message Error
1 YES “Err” Collective information on a group of errors / incidents
2 YES “Open” Enclosure opening (incident)
3 YES “EXT” Information on connected external sensor
4 YES “ ” Operation time exceeded - battery is empty
→ A heat cost allocator with data presentation switched off (data presentation in a loop, with messages displayed
one by one)
→ Factory’s settings (no configuration)
→ Stand-by mode - information displayed between the configuration to the start of the accounting
→ Seal application
→ The heat cost allocator initiated to display in a basic mode or in an extended mode (continuous presentation all the
time of the basic mode):
7 HYDROCLIMA 2 - User Manual
Examples of indications:
Display test - all segments on
Display test - all segments off
Present consumption [C]
Data for a terminated clearing
period
Average ambient temp. for a
present period
Average ambient temp. for a
terminated period
The second adjustment coeffi -
cient (KQ)
Opening date of a clearing period
Closing date of a clearing period
Control code
Serial number last 6 digits
Collective information on a group
of errors/frauds and information
on a present consumption
The first adjustment coefficient
(KC)
Information that the heat cost
allocator operates with
an external sensor and present
consumption
Operation time exceeded -
battery is empty with a
present consumptions
Seal application
Opening of the seal and informa -
tion on present consumption have
been recorded
Stand-by mode
Configuration received
Radio frequency mode
8 HYDROCLIMA 2 - User Manual
Button
Alarms
The timing of button pressure corresponds to the following events:
In the status field we have an error/event report. Possible errors / events are listed in the table.
→ Non-configured heat cost allocator (factory settings); Pressing the button for the first time prepares the device to
receive the configuration data. After a successful configuration the “CONF” information appears in the display.
→ Previously configured heat cost allocator (normal operation mode):
¬ Pushing of the button not longer than 2 seconds - initiation of the display basic data described in the previous
chapter
¬ Pushing of the button longer than 3 seconds - initiation of the display extended data described in the previous
chapter
¬ Pushing of the button longer than 5 seconds - the allocator activate rf transmitting mode that allow the
communication with software in two modes:
~ Change of the operation configuration. Successful configuration is confirmed by “CONF” information
displayed in the display for 10 s. In case the configuration is not successful, it is necessary to release the
button and push it again
~ Sending of the following extended data:
· a pack including history of units memorized at the end of 24 previously months
· a pack including a history of average temperatures for recent 24 months
· a pack comprising all data stored in the memory of the heat cost allocator
Event/Error Description
C 15 Power failure has been recorded. Power supply has been temporarily lost, all data has been restored from non-volatile memory.
C 13 A quartz oscillator malfunction event has been recorded. Flag deleted automatically after date and time update.
C 11 The overflow of the heat consumption indication parameter [C] was recorded. Closing the billing period does not clear this flag,
therefore the overflow event may also relate to the past period.
C 10 Reduced temperature was recorded for a longer period (radiator temperature parameter TK). The value of the TK radiator
temperature parameter below 16 °C was registered for a period longer than 24h.
C 9 Exceeding the range of permissible temperature values (radiator temperature parameter TK).
Permitted temperature range is: <5 °C ... 95 °C>
B 8 An open case event was recorded, the date of first occurrence is recorded. Clearing this flag also resets the date of occurrence. The
flag can be cleared automatically in the event of the first seal application after the configuration process.
A 1 State of verification of the opening sensor and button. The flag is cleared automatically after closing the cover and pressing the
button.
A 0 Default configuration parameter values. Device not configured or data from non-volatile memory lost; flag cleared automatically
after the configuration process.
9 HYDROCLIMA 2 - User Manual
Configuration
Technical data
* The battery life strongly depends on the working time window, set during the configuration process, and on the
environmental conditions. Estimation of the battery life is given by the configuration software.
Programming and configuration of the device is carried out by radio, using an RFM-RX2 and BMetering software.
To trigger the configuration procedure, the BMetering software must be properly configured:
→ For the factory state of the allocator, press the button for < 1s,
→ For the allocator already configured, press the button for > 5s, until the display shows the message “rF”.
The method of configuration has been described in the documentation concerning the B Metering software
user manual
Type Hydroclima 2, electronic, two-sensor one
Available versions Compact, with an external temperature probe
LCD 7 segment display with icons
Dimensions 102 mm x 40 mm x 27 mm (h x w x d)
Power supply Lithium battery 3.6V
Maximum battery life 10 Years*
Application temperatures
From 35°C to 105°C
From 35°C to 130°C (version with a remote sensor, length of the sensor
3m)
Accuracy of the measurement Temperature Sensors – thermistors 1%
Way of reading Physical (display)
Radio (remote)
Communication with the device Radio, two-ways directions
Configuration Radio configuration, via Bmetering software and RFM-RX2
Power of the transmitter 10 dBm (10 Mw)
Frequency of the transmitter 868,950 Mhz
Frequency of the receiver 868,300 Mhz
Start accounting ( thermal energy consumption units)
Radiator’s temperature > 22.5°C
Δt ≥3k (difference between a temp. Of a radiator and the ambient
temp.)
Measurement method Two-sensor or single sensor (depending of the conditions)
10 HYDROCLIMA 2 - User Manual
Dimensions and drawings
12 HYDROCLIMA 2 - User Manual
Contacts
B METERS srl
Via Friuli, 3 • Gonars 33050 (UD) • ITALY
Tel: +39 0432 931415
Tel: +39 0432 1690412
Fax: +39 0432 992661
E-mail (sales/info): info@bmeters.com
E-mail (support): ticket@bmeters.com
Web: www.bmeters.com