Diehl Sharky 774 Installation Manual.pdf
DIEHL
Metering
Ultrasonic energy meter
Contatore di energia ad ultra suoni
Ultraljuds-energimatare
Installation guide
Istruzioni per il montaggio
Installationsvejledning
Monteringsanvisning
©. =
This guide must pm 000909090000
be given to the end pon 00000
consumer. =
skal afleveres til monteren.
=) = =
a
1 2 A B AB
Table of content
2. Transport and storage.........cccoouurmrrrmrmmmmnrssssssssssssssnsnsnsssnnnes 3
3. Installation of energy meter (fig. I)...coivmmmmmsmsnmnininnninnnnnn 5
4.1 Installation in the ball valve with adapter.........cccccevveveiveeennneeo. 8
5.1 Inlet / outlet setting (optional ex works) ..........cccceeeevviiieeeenrennn. 10
6.1 Communication Via radio ......ccecevrinirieninsiriereseeienineeesssnseessennns 12
6.2 M-Bus Communication module.........cceeinniiviininininnnnn., 12
9. Display Error Codes ....cuiciemmmmmmnmmmniasssssissssssssssssssssssnsssnssns 14
11. Declaration of conformity for MID meters.......c.ccvnrininnnns 15
1. General
This guide is intended for trained specialised personnel. Therefore, it does
not include basic working steps.
The seal on the energy meter must not be damaged!
(1) A damaged seal will result in immediate invalidation of the factory
warranty and verification. The cables supplied with the meter
must neither be shortened, extended nor changed in any other way.
Legal regulations and operating instructions for the use of energy
(1) meters must be observed!
The installation must only be carried out by a specialist energy
meter installation and electrical company. The personnel must
be trained in the installation and handling of energy meters and electrical
devices as well as the applicable guidelines.
Medium: Water, according to CEN/TR 16911.
If water additives are used (e.g. corrosion protection), the user must
make sure that the corrosion resistance is adequate.
This product is designated (where relevant) as a pressure main-
(1) taining component in the sense of the Pressure Equipment Direc-
tive (PED) and may only be operated as a pressure maintaining
component with temperature sensors suitable for this purpose.
This product is not intended for used as a safety device in the sense of the
Pressure Equipment Directive (PED).
® The medium temperature is specified as 5 ... 105 °C (130 °C)
® The temperature range depends on variant and nominal size.
® The exact temperature range is shown on the type plate.
® The encapsulated variant is to be used if condensation is expected.
® The operating/ambient conditions are 5 ... 55 °C; IP 54/65; 93 % rel.
humidity.
® Ambient temperatures below 35 °C have a positive effect on battery
lifetime.
If the flow sensor is insulated with the pipeline, the calculator
(1) must be accessible.
Detailed user guide available at https://www.diehl.com/metering/en/
support-center/download-center/.
The Software IZAR@Mobile2 is used for reading out data and configuration
and can be downloaded from the Internet under:
https://www.diehl.com/metering/en/support-center/download-center/
Changing of communication relevant parameters can result in
the loss of OMS certification.
2. Transport and storage
Unpacking
Energy meters are measuring devices and must be handled with care. To
protect against damage and soiling, they should only be unpacked imme-
diately prior to installation.
Transport
The transport of the meter is permitted only in the original package.
When sending wireless measuring instruments / components by
air, disable the wireless (place in aircraft mode) before shipping.
3. Installation of energy meter (fig. I)
® Depending on the design and application (heat or cooling meter), the
energy meter is installed in either the hot or cold line of the system.
® The flow sensor must be installed so that the flow direction matches
the arrow direction on the sensor.
B Depending on the version, the flow sensor must be installed in inlet or
outlet. The installation position is displayed in the info loop 3.4 (see
"Information loop (3)" on page 14) and, if necessary, also by means
of a pictogram.
no pictogram
) =<) (Installation position
can be set on site,
Inlet Outlet 5.1 on page 10
® Calming sections are not necessary before and after the flow sensor.
For systems without temperature mixing, a straight calming section of
3-10 x DN upstream of the flow sensor is recommended.
The meter can be installed in both horizontal and vertical pipe
(1) sections, provided air bubbles cannot collect in the meter.
The flow sensor must always be filled with liquid.
Avoid frost at the meter.
m We recommend installing the flow sensor in a tilted position.
® The minimum system pressure must be 1 bar to avoid cavitation.
B® Electrical and magnetic fields might disrupt electronic components
in the energy metering device. Make sure there is sufficient distance
(approx. 10 cm) between the calculator and its measurement signal
lines and possible sources of electromagnetic disturbance (e.g. trans-
formers, electric motors, supply lines, etc.).
® If possible install the cables of the flow sensor or temperature sensor
freely suspended (not bundled - aerial effect) with sufficient distance
from electromagnetic interference sources.
® The measurement signal lines (temperature and flow rate) must not
be routed in direct proximity to other lines, such as mains supply lines,
low-voltage supply lines and data transmission cables. The minimum
distance of 5 cm for low-voltage lines must be observed according to
EN 1434-6.
® For medium temperatures from 90°C or for T,__<T, (cooling
meter application or heat meter with cooling tariff application) the cal-
culator must be removed and fitted at a sufficient distance from any
heat sources. A wall holder (optional) or a spacer holder (optional) is
available for this purpose.
Spacer holder Wall mounting
® It is recommended that shut-off valves are fitted before and after the
energy meter to simplify removing the meter.
® The meter should be installed in a conveniently accessible position for
service and operating personnel.
®m Initial operation is to be carried out and recorded after installation.
=
4. Temperature sensor
Handle the temperature sensor carefully!
(1) The sensor cables are provided with coloured type plates:
® Red: Sensor in the hot line
® Blue: Sensor in the cold line
® It is not permissible to shorten or lengthen the connection lines.
® The free temperature sensors can be installed directly immersed (e.g.
ball valve) or in an immersion sleeve that has been conformity tested
for this sensor type.
® The sensors should preferably be installed symmetrically.
® The following limit values apply to asymmetrically thermally insu-
lated installations:
gp 0.6 m3/h=>10K > 301/h...5K > 1201/h
gp 1.5 m3/h=>10K > 151/h...5K > 150 I/h
gp 2.5 m3/h => 10K > 30 I/h....3 K> 250 I/h
® The following limit values apply to asymmetrical, thermally uninsu-
lated installation:
gp 0.6 m3/h => this type of installation is not permissible!
gp 1.5 m3/h => 10 K > 1501 /h
gp 2.5 m3/h => 5K > 2501/h
4.1 Installation in the ball valve with adapter
(coupling set in a separate bag)
Use ball valves with installation option for temperature sensor with thread
M10 x 1.
Preparatory measures
® (Close the ball valve.
® Unscrew the plug screw from the ball valve.
Installation (see fig. II)
1. Place the O-ring from the attached coupling set (type A or B) on the
mounting pin.
2. Insert the O-ring with the mounting pin into the sensor hole of the ball
valve (turn the mounting pin).
3. Position the O-ring in its final position using the other end of the
mounting pin.
-8-
4. Fastening screws
® Type A (plastic) - plug the fastening screw onto the temperature sensor.
® Type B (brass) - insert the temperature sensor in the fastening screw
and place the sensor in the mounting pin. Press in the dowel pin com-
pletely and remove the mounting pin.
5. Insert the temperature sensor with the securing fitting in the ball
valve and manually tighten (2-3 Nm).
4.2 Installation in a pocket
It is recommended that temperature sensors for DN25 rated sizes or
smaller are only fitted in new installations such that they are directly
immersed.
This ensures higher measuring accuracy.
5. Start-up operation
Once the meter has been installed, the components (calculator, volume
measuring component and both temperature sensors) must be sealed
with a tamper-proof seal and the meter started up by a specialist com-
pany approved according to the legislation.
| CERTIFIED (& Bos LZ |
-9-
® Check the display for a plausible indication of flow rate and temper-
atures.
User guide for further Information is available at
https://www.diehl.com/metering/en/support-center/download-center/
5.1 Inlet / outlet setting (optional ex works)
Optionally, the installation position of the meter can be set in-situ in loop 3
("3.4" on page 14). Consequently installation in the inlet (flow) or outlet
(return) is possible.
(1] This setting must be made prior to initial operation of the meter.
As supplied, the outlet (return) is pre-set and is shown as follows in the
display.
Setting and number of possi-
oo, = ble changes.
To changeover, switch to the "Outlet" window in loop 3 (see "8. Opera-
tion" on page 14).
Pressing and holding the button for > 6 s changes the display/setting to
"Inlet".
This setting can be changed a total of 8 times by pressing the button.
The display changes during the 6 s.
This does not influence functioning.
-10-
Sequence during changing
i A a THA 4 A
Button pressed <3s Button pressed >3s
If the button is pressed and then held for > 6 s, the meter performs the
command shown in the display.
In each change, the framed
I nim = number in the display is
reduced by 1.
After 8 changes, it is no longer possible to change the installation position.
The possibility of changing lapses either immediately upon
detection of water, or after three hours’ operation without error
detection (pre-set ex works).
The following indication appears in the display (example):
The changes indication dis-
= appears.
3 8A
When changing the installation position, the sensors must be
matched to the actual installation (see "4. Temperature sensor"
on page 8).
-11-
6. Communication
Communication modules must be secured so that opening of
(1) meters is only possible by destroying the securing points.
The calculator supports two communication channels (radio (wireless) or M-Bus).
The protocols may be different for all two communication channels and
are pre-set ex works. The telegrams can be defined for each customer
using the IZAR@MOBILE 2 software.
6.1 Communication via radio
The integrated radio module is an interface for communication with Diehl
Metering radio receivers.
Unidirectional communication has the following specification:
® The module transmits every 8 ... 256 s (send period max. 0.1 %
of duty cycle (min. 8s); variable, depending on protocol length and
programming)
® The communication always transfers the currently measured data
B Transmission frequencies:
— 434 MHz, transmission power (EN 300 220-2 v3.2.1): 10mW e.r.p.
— 868 MHz, transmission power (EN 300 220-2 V3.2.1): 25mW e.r.p.
® Various Diehl Metering receivers are available for receiving the proto-
col (e.g. Bluetooth, GPRS, LAN, ...)
® The protocol corresponds to OMS Profile A or Profile B and is
encrypted.
® Reading modes: Walk-By, Drive-By, Fixed-Network
B® For problematic radio installations (shield) the external wireless mod-
ule set can also be used
6.2 M-Bus Communication module
The M-Bus communication module is a serial interface for communication
with external devices (M-Bus control centres), e.g. IZAR CENTER. A num-
ber of meters can be connected to a control centre.
B The connection is not polarity-sensitive and is electrically isolated
m M-Bus protocol standardised according to EN 1434;
® 300 or 2400 baud (auto baud detect)
Bm Connection for 2 x 2.5 mm?2;
® Power consumption: One M-Bus load
-12-
7. Display
The data generated by the calculator can be viewed in several displays. These
displays contain the assigned system information (e.g. energy quantities,
water volumes, operating days, water quantities, actual temperatures, max-
imum values) and can be accessed by calling the displays in the pre-defined
sequence / loop. The energy meter has up to 6 different display sequences.
Main loop, due date loop, information loop, month loop.
The month loop comprises up to seven readings alternatingly displayed
for 2 s-4s each. For quick visual identification, the loops are labelled
1 to 6 in the display. As standard, the main loop contains the actual
data, e.g. energy, volume, flow and temperatures. The verified register is
marked with a padlock icon.
Main loop (1)
Sequence | Window 1 Window 2
1.1 Accumulated energy
1:2 Accumulated cold energy (heat meters
with cooling tariff)
14
1.6 Flow temperature Return flow temperature **)
Return flow temperature *)
17
1.8 Operating days
L.9 Error hours
1.10
*) without a decimal place; **) with one decimal place respectively
Due date loop (2)
Sequence | Window 1 Window 2 Window 3
2.1 "Accd 1"
2.2 Date of future due date 1
2:3 Due date 1 previous Due date 1 previous year |"Accd 1L"
year date energy
2.4 Due date 2 date Due date 2 energy "Accd 2A"
2:5 Date of future due date 2
2.6 Due date 2 previous Due date 2 previous year | "Accd 2L"
year date energy
Information loop (3)
Sequence | Window 1 | Window 2
32 Secondary address
33 Primary address
3.4 depending on the setting (5.1 on page
10) -
3.5 "UHF ON" (status of integrated radio)
36 Check sum
Tariff loop (5) *
Month loop (6)
Sequence | Window 1 | Window 2 | Window 3 | Window 4
6.2 Volume
624 Volume
* Example | 10nly for heat meters with activated cooling tariff
8. Operation
Use the push button to page through the individual displays. When doing
so a differentiation is made between short and long button presses. With a
short button press (<3 seconds) you get to the next display within a loop;
with a long button press (>3 seconds) you get to the next display loop.
The "Energy" window (sequence 1.1) of the main loop is the basic display.
If the button is not pressed for approx.4 minutes, the meter automatically
switches off the display to save power (exception: an error exists). If you
press the button again, the meter returns to the basic display.
9. Display Error codes
If an error occurs, the error code is displayed in the main loop. All win-
dows, however, can still be accessed by pressing the button. If the button
is not pressed for approx. 4 min, the error code is automatically displayed
again.
The error message disappears automatically as soon as the source of the
error is corrected. All errors that exist for longer than 6 min, are saved in
the error memory.
-14-
Error code Description
C-1 Basic parameter error in flash or RAM - Meter must be replaced
El Temperature range outside [-19.9 °C...199.9 °C] e.g. sensor short-circuit,
sensor break
E 3* Forward and return sensor reversed
E4 Hardware error US measurement, e.g. transducer or control defective or short
circuit
ES Communication not possible (too frequent read-out)
E 6* Flow direction of flow meter incorrect
E7 No plausible ultrasound receiver signal, e.g. air in the measuring path
EQ Battery nearly discharged, design lifetime reached
* application dependent
10. Disposal
The transposed European Directives on waste batteries and waste electri-
cal and electronic equipment supervise the actions necessary to limit the
negative impact of the product end of life.
This product is subject to special collection and disposal. It should be
deposited at an appropriate facility to enable recovery and recycling.
For further details about recycling this product, please contact your Diehl
Metering agency.
11. Declaration of conformity for MID meters
See from page 55 onwards.
Further information as well as the actual declaration of conformity are
available at:
https://www.diehl.com/metering/en/support-center/download-center/
-15-
DIEHL
Metering
Ultrasonic energy meter
Contatore di energia ad ultra suoni
Ultraljuds-energimatare
Installation guide
Istruzioni per il montaggio
Installationsvejledning
Monteringsanvisning
©. =
This guide must 000909090000
be given to the end pon 00000
consumer. =
skal afleveres til monteren.
=) = =
a
1 2 A B AB
Table of content
2. Transport and 3
3. Installation of energy meter (fig. 5
4.1 Installation in the ball valve with 8
5.1 Inlet / outlet setting (optional ex works) 10
6.1 Communication Via radio 12
6.2 M-Bus Communication 12
9. Display Error Codes 14
11. Declaration of conformity for MID 15
1. General
This guide is intended for trained specialised personnel. Therefore, it does
not include basic working steps.
The seal on the energy meter must not be damaged!
(1) A damaged seal will result in immediate invalidation of the factory
warranty and verification. The cables supplied with the meter
must neither be shortened, extended nor changed in any other way.
Legal regulations and operating instructions for the use of energy
(1) meters must be observed!
The installation must only be carried out by a specialist energy
meter installation and electrical company. The personnel must
be trained in the installation and handling of energy meters and electrical
devices as well as the applicable guidelines.
Medium: Water, according to CEN/TR 16911.
If water additives are used (e.g. corrosion protection), the user must
make sure that the corrosion resistance is adequate.
This product is designated (where relevant) as a pressure main-
(1) taining component in the sense of the Pressure Equipment Direc-
tive (PED) and may only be operated as a pressure maintaining
component with temperature sensors suitable for this purpose.
This product is not intended for used as a safety device in the sense of the
Pressure Equipment Directive (PED).
® The medium temperature is specified as 5 ... 105 °C (130 °C)
® The temperature range depends on variant and nominal size.
The exact temperature range is shown on the type plate.
® The encapsulated variant is to be used if condensation is expected.
® The operating/ambient conditions are 5 ... 55 °C; IP 54/65; 93 % rel.
humidity.
® Ambient temperatures below 35 °C have a positive effect on battery
lifetime.
If the flow sensor is insulated with the pipeline, the calculator
(1) must be accessible.
Detailed user guide available at https://www.diehl.com/metering/en/
support-center/download-center/.
The Software IZAR@Mobile2 is used for reading out data and configuration
and can be downloaded from the Internet under:
https://www.diehl.com/metering/en/support-center/download-center/
Changing of communication relevant parameters can result in
the loss of OMS certification.
2. Transport and storage
Unpacking
Energy meters are measuring devices and must be handled with care. To
protect against damage and soiling, they should only be unpacked imme-
diately prior to installation.
Transport
The transport of the meter is permitted only in the original package.
When sending wireless measuring instruments / components by
air, disable the wireless (place in aircraft mode) before shipping.
3. Installation of energy meter (fig. I)
Depending on the design and application (heat or cooling meter), the
energy meter is installed in either the hot or cold line of the system.
® The flow sensor must be installed so that the flow direction matches
the arrow direction on the sensor.
B Depending on the version, the flow sensor must be installed in inlet or
outlet. The installation position is displayed in the info loop 3.4 (see
"Information loop (3)" on page 14) and, if necessary, also by means
of a pictogram.
no pictogram
) (Installation position
can be set on site,
Inlet Outlet 5.1 on page 10
® Calming sections are not necessary before and after the flow sensor.
For systems without temperature mixing, a straight calming section of
3-10 x DN upstream of the flow sensor is recommended.
The meter can be installed in both horizontal and vertical pipe
(1) sections, provided air bubbles cannot collect in the meter.
The flow sensor must always be filled with liquid.
Avoid frost at the meter.
We recommend installing the flow sensor in a tilted position.
® The minimum system pressure must be 1 bar to avoid cavitation.
Electrical and magnetic fields might disrupt electronic components
in the energy metering device. Make sure there is sufficient distance
(approx. 10 cm) between the calculator and its measurement signal
lines and possible sources of electromagnetic disturbance (e.g. trans-
formers, electric motors, supply lines, etc.).
® If possible install the cables of the flow sensor or temperature sensor
freely suspended (not bundled - aerial effect) with sufficient distance
from electromagnetic interference sources.
® The measurement signal lines (temperature and flow rate) must not
be routed in direct proximity to other lines, such as mains supply lines,
low-voltage supply lines and data transmission cables. The minimum
distance of 5 cm for low-voltage lines must be observed according to
EN 1434-6.
® For medium temperatures from 90°C or for T,__<T, (cooling
meter application or heat meter with cooling tariff application) the cal-
culator must be removed and fitted at a sufficient distance from any
heat sources. A wall holder (optional) or a spacer holder (optional) is
available for this purpose.
Spacer holder Wall mounting
® It is recommended that shut-off valves are fitted before and after the
energy meter to simplify removing the meter.
The meter should be installed in a conveniently accessible position for
service and operating personnel.
Initial operation is to be carried out and recorded after installation.
=
4. Temperature sensor
Handle the temperature sensor carefully!
(1) The sensor cables are provided with coloured type plates:
Red: Sensor in the hot line
® Blue: Sensor in the cold line
It is not permissible to shorten or lengthen the connection lines.
The free temperature sensors can be installed directly immersed (e.g.
ball valve) or in an immersion sleeve that has been conformity tested
for this sensor type.
The sensors should preferably be installed symmetrically.
The following limit values apply to asymmetrically thermally insu-
lated installations:
gp 0.6 > 1201/h
gp > 151/h...5K > 150 I/h
gp > 30 K> 250 I/h
® The following limit values apply to asymmetrical, thermally uninsu-
lated installation:
gp 0.6 m3/h => this type of installation is not permissible!
gp 1.5 m3/h => 10 K > 1501 /h
gp 2.5 m3/h > 2501/h
4.1 Installation in the ball valve with adapter
(coupling set in a separate bag)
Use ball valves with installation option for temperature sensor with thread
M10 x 1.
Preparatory measures
(Close the ball valve.
Unscrew the plug screw from the ball valve.
Installation (see fig. II)
1. Place the O-ring from the attached coupling set (type A or B) on the
mounting pin.
2. Insert the O-ring with the mounting pin into the sensor hole of the ball
valve (turn the mounting pin).
3. Position the O-ring in its final position using the other end of the
mounting pin.
-8-
4. Fastening screws
Type A (plastic) -
plug the fastening screw onto the temperature sensor.
Type B (brass) - insert the temperature sensor in the fastening screw
and place the sensor in the mounting pin. Press in the dowel pin com-
pletely and remove the mounting pin.
5. Insert the temperature sensor with the securing fitting in the ball
valve and manually tighten (2-3 Nm).
4.2 Installation in a pocket
It is recommended that temperature sensors for DN25 rated sizes or
smaller are only fitted in new installations such that they are directly
immersed.
This ensures higher measuring accuracy.
5. Start-up operation
Once the meter has been installed, the components (calculator, volume
measuring component and both temperature sensors) must be sealed
with a tamper-proof seal and the meter started up by a specialist com-
pany approved according to the legislation.
CERTIFIED (& |
-9-
Check the display for a plausible indication of flow rate and temper-
atures.
User guide for further Information is available at
https://www.diehl.com/metering/en/support-center/download-center/
5.1 Inlet / outlet setting (optional ex works)
Optionally, the installation position of the meter can be set in-situ in loop 3
("3.4" on page 14). Consequently installation in the inlet (flow) or outlet
(return) is possible.
(1] This setting must be made prior to initial operation of the meter.
As supplied, the outlet (return) is pre-set and is shown as follows in the
display.
Setting and number of possi-
= ble changes.
To changeover, switch to the "Outlet" window in loop 3 (see "8. Opera-
tion" on page 14).
Pressing and holding the button for > 6 s changes the display/setting to
"Inlet".
This setting can be changed a total of 8 times by pressing the button.
The display changes during the 6 s.
This does not influence functioning.
-10-
Sequence during changing
i A a 4 A
Button pressed <3s Button pressed >3s
If the button is pressed and then held for > 6 s, the meter performs the
command shown in the display.
In each change, the framed
I number in the display is
reduced by 1.
After 8 changes, it is no longer possible to change the installation position.
The possibility of changing lapses either immediately upon
detection of water, or after three hours' operation without error
detection (pre-set ex works).
The following indication appears in the display (example):
The changes indication dis-
appears.
3
When changing the installation position, the sensors must be
matched to the actual installation (see "4. Temperature sensor"
on page 8).
-11-
6. Communication
Communication modules must be secured so that opening of
(1) meters is only possible by destroying the securing points.
The calculator supports two communication channels (radio (wireless) or M-Bus).
The protocols may be different for all two communication channels and
are pre-set ex works. The telegrams can be defined for each customer
using the IZAR@MOBILE 2 software.
6.1 Communication via radio
The integrated radio module is an interface for communication with Diehl
Metering radio receivers.
Unidirectional communication has the following specification:
® The module transmits every 8 ... 256 s (send period max. 0.1 %
of duty cycle (min. 8s); variable, depending on protocol length and
programming)
® The communication always transfers the currently measured data
B Transmission frequencies:
434 MHz, transmission power (EN 300 220-2 10mW e.r.p.
868 MHz, transmission power (EN 300 220-2 V3.2.1): 25mW e.r.p.
Various Diehl Metering receivers are available for receiving the proto-
col (e.g. Bluetooth, GPRS, LAN, ...)
® The protocol corresponds to OMS Profile A or Profile B and is
encrypted.
® Reading modes: Walk-By, Drive-By, Fixed-Network
For problematic radio installations (shield) the external wireless mod-
ule set can also be used
6.2 M-Bus Communication module
The M-Bus communication module is a serial interface for communication
with external devices (M-Bus control centres), e.g. IZAR CENTER. A num-
ber of meters can be connected to a control centre.
B The connection is not polarity-sensitive and is electrically isolated
protocol standardised according to EN 1434;
® 300 or 2400 baud (auto baud detect)
Connection for 2 x 2.5 mm?2;
® Power consumption: One M-Bus load
-12-
7. Display
The data generated by the calculator can be viewed in several displays. These
displays contain the assigned system information (e.g. energy quantities,
water volumes, operating days, water quantities, actual temperatures, max-
imum values) and can be accessed by calling the displays in the pre-defined
sequence / loop. The energy meter has up to 6 different display sequences.
Main loop, due date loop, information loop, month loop.
The month loop comprises up to seven readings alternatingly displayed
for 2 s-4s each. For quick visual identification, the loops are labelled
1 to 6 in the display. As standard, the main loop contains the actual
data, e.g. energy, volume, flow and temperatures. The verified register is
marked with a padlock icon.
Main loop (1)
Sequence | Window 1 Window 2
1.1 Accumulated energy
1:2 Accumulated cold energy (heat meters
with cooling tariff)
14
1.6 Flow temperature Return flow temperature **)
Return flow temperature *)
17
1.8 Operating days
L.9 Error hours
1.10
*) without a decimal place; **) with one decimal place respectively
Due date loop (2)
Sequence | Window 1 Window 2 Window 3
2.1 "Accd 1"
2.2 Date of future due date 1
2:3 Due date 1 previous Due date 1 previous year |"Accd 1L"
year date energy
2.4 Due date 2 date Due date 2 energy "Accd 2A"
2:5 Date of future due date 2
2.6 Due date 2 previous Due date 2 previous year 2L"
year date energy
Information loop (3)
Sequence |
Window 1 | Window 2
32 Secondary address
33 Primary address
3.4 depending on the setting (5.1 on page
10) - 3.5 "UHF ON" (status of integrated radio)
36 Check sum
Tariff loop (5) *
Month loop (6)
Sequence | Window 1 | Window 2 | Window 3 | Window 4
6.2 Volume
624 Volume
* Example | 10nly for heat meters with activated cooling tariff
8. Operation
Use the push button to page through the individual displays. When doing
so a differentiation is made between short and long button presses. With a
short button press (<3 seconds) you get to the next display within a loop;
with a long button press (>3 seconds) you get to the next display loop.
The "Energy" window (sequence 1.1) of the main loop is the basic display.
If the button is not pressed for approx.4 minutes, the meter automatically
switches off the display to save power (exception: an error exists). If you
press the button again, the meter returns to the basic display.
9. Display Error codes
If an error occurs, the error code is displayed in the main loop. All win-
dows, however, can still be accessed by pressing the button. If the button
is not pressed for approx. 4 min, the error code is automatically displayed
again.
The error message disappears automatically as soon as the source of the
error is corrected. All errors that exist for longer than 6 min, are saved in
the error memory.
-14-
Error code Description
C-1 Basic parameter error in flash or RAM - Meter must be replaced
El Temperature range outside [-19.9 °C...199.9 °C] e.g. sensor short-circuit,
sensor break
E 3* Forward and return sensor reversed
E4 Hardware error US measurement, e.g. transducer or control defective or short
circuit
ES Communication not possible (too frequent read-out)
E 6* Flow direction of flow meter incorrect
E7 No plausible ultrasound receiver signal, e.g. air in the measuring path
EQ Battery nearly discharged, design lifetime reached
* application dependent
10. Disposal
The transposed European Directives on waste batteries and waste electri-
cal and electronic equipment supervise the actions necessary to limit the
negative impact of the product end of life.
This product is subject to special collection and disposal. It should be
deposited at an appropriate facility to enable recovery and recycling.
For further details about recycling this product, please contact your Diehl
Metering agency.
11. Declaration of conformity for MID meters
See from page 55 onwards.
Further information as well as the actual declaration of conformity are
available at:
https://www.diehl.com/metering/en/support-center/download-center/
-15-
Ultrasonic energy meter
Contatore di energia ad ultra suoni
Ultralydsenergimålere
Ultraljuds-energimätare Installation guide
Istruzioni per il montaggio
Installationsvejledning
Monteringsanvisning
English Italiano Dansk Svenska This guide must
be given to the end
consumer. Consegnare
queste istruzioni al cliente
finale. Denne vejledning
skal afleveres til montøren.
Denna bruksanvisning
ska överlämnas till
kunden.
-2- English Italiano Dansk Svenska
II
I
2 1
4 3
5
A B
A B A B
-3- English Italiano Dansk Svenska
Table of content
1. General ...............................................................................4
2. Transport and storage ........................................................5
3. Installation of energy meter (fig. I) ...................................5
4. Temperature sensor ...........................................................8
4.1 Installation in the ball valve with adapter ................................... 8
4.2 Installation in a pocket ............................................................. 9
5. Start-up operation ..............................................................9
5.1 Inlet / outlet setting (optional ex works) .................................. 10
6. Communication ................................................................12
6.1 Communication via radio ........................................................ 12
6.2 M-Bus Communication module ................................................ 12
7. Display ..............................................................................13
8. Operation .........................................................................14
9. Display Error codes ..........................................................14
10. Disposal ............................................................................15
11. Declaration of conformity for MID meters .......................15
11.1 EU DoC 774/3 ........................................................................ 55
11.2 EU DoC 774 noMID/2 ............................................................. 57
-4- English Italiano Dansk Svenska
1. General
This guide is intended for trained specialised personnel. Therefore, it does
not include basic working steps.
The seal on the energy meter must not be damaged!
A damaged seal will result in immediate invalidation of the factory
warranty and verification. The cables supplied with the meter
must neither be shortened, extended nor changed in any other way.
Legal regulations and operating instructions for the use of energy
meters must be observed!
The installation must only be carried out by a specialist energy
meter installation and electrical company. The personnel must
be trained in the installation and handling of energy meters and electrical
devices as well as the applicable guidelines.
Medium: Water, according to CEN/TR 16911.
If water additives are used (e.g. corrosion protection), the user must
make sure that the corrosion resistance is adequate.
This product is designated (where relevant) as a pressure main-
taining component in the sense of the Pressure Equipment Direc-
tive (PED) and may only be operated as a pressure maintaining
component with temperature sensors suitable for this purpose.
This product is not intended for used as a safety device in the sense of the
Pressure Equipment Directive (PED).
The medium temperature is specified as 5 ... 105 °C (130 °C)
The temperature range depends on variant and nominal size.
The exact temperature range is shown on the type plate.
The encapsulated variant is to be used if condensation is expected.
The operating/ambient conditions are 5 … 55 °C; IP 54/65; 93 % rel.
humidity.
Ambient temperatures below 35 °C have a positive effect on battery
lifetime.
If the flow sensor is insulated with the pipeline, the calculator
must be accessible.
-5- English Italiano Dansk Svenska
Detailed user guide available at https://www.diehl.com/metering/en/
support-center/download-center/.
The Software IZAR@Mobile2 is used for reading out data and configuration
and can be downloaded from the Internet under:
https://www.diehl.com/metering/en/support-center/download-center/
Changing of communication relevant parameters can result in
the loss of OMS certification.
2. Transport and storage
Unpacking
Energy meters are measuring devices and must be handled with care. To
protect against damage and soiling, they should only be unpacked imme-
diately prior to installation.
Transport
The transport of the meter is permitted only in the original package.
When sending wireless measuring instruments / components by
air, disable the wireless (place in aircraft mode) before shipping.
3. Installation of energy meter (fig. I)
Depending on the design and application (heat or cooling meter), the
energy meter is installed in either the hot or cold line of the system.
The flow sensor must be installed so that the flow direction matches
the arrow direction on the sensor.
Depending on the version, the flow sensor must be installed in inlet or
outlet. The installation position is displayed in the info loop 3.4 (see
"Information loop (3)" on page 14) and, if necessary, also by means
of a pictogram.
-6- English Italiano Dansk Svenska
no pictogram
(Installation position
can be set on site,
5.1 on page 10) Inlet Outlet
Calming sections are not necessary before and after the flow sensor.
For systems without temperature mixing, a straight calming section of
3-10 x DN upstream of the flow sensor is recommended.
The meter can be installed in both horizontal and vertical pipe
sections, provided air bubbles cannot collect in the meter.
The flow sensor must always be filled with liquid.
Avoid frost at the meter.
We recommend installing the flow sensor in a tilted position.
The minimum system pressure must be 1 bar to avoid cavitation.
Electrical and magnetic fields might disrupt electronic components
in the energy metering device. Make sure there is sufficient distance
(approx. 10 cm) between the calculator and its measurement signal
lines and possible sources of electromagnetic disturbance (e.g. trans-
formers, electric motors, supply lines, etc.).
If possible install the cables of the flow sensor or temperature sensor
freely suspended (not bundled - aerial effect) with sufficient distance
from electromagnetic interference sources.
The measurement signal lines (temperature and flow rate) must not
be routed in direct proximity to other lines, such as mains supply lines,
low-voltage supply lines and data transmission cables. The minimum
distance of 5 cm for low-voltage lines must be observed according to
EN 1434-6.
-7- English Italiano Dansk Svenska
T: 5 … 90 °C
T water > T ambient
T: 5 … 105 / 130 °C
T water < T ambient
For medium temperatures from 90°C or for T Water <T Ambient (cooling
meter application or heat meter with cooling tariff application) the cal -
culator must be removed and fitted at a sufficient distance from any
heat sources. A wall holder (optional) or a spacer holder (optional) is
available for this purpose.
Spacer holder Wall mounting
It is recommended that shut-off valves are fitted before and after the
energy meter to simplify removing the meter.
The meter should be installed in a conveniently accessible position for
service and operating personnel.
Initial operation is to be carried out and recorded after installation.
-8- English Italiano Dansk Svenska
4. Temperature sensor
Handle the temperature sensor carefully!
The sensor cables are provided with coloured type plates:
Red: Sensor in the hot line
Blue: Sensor in the cold line
It is not permissible to shorten or lengthen the connection lines.
The free temperature sensors can be installed directly immersed (e.g.
ball valve) or in an immersion sleeve that has been conformity tested
for this sensor type.
The sensors should preferably be installed symmetrically.
The following limit values apply to asymmetrically thermally insu-
lated installations:
qp 0.6 m³/h => 10 K > 30 l/h....5 K > 120 l/h
qp 1.5 m³/h => 10 K > 15 l/h....5 K > 150 l/h
qp 2.5 m³/h => 10 K > 30 l/h....3 K > 250 l/h
The following limit values apply to asymmetrical, thermally uninsu-
lated installation:
qp 0.6 m³/h => this type of installation is not permissible!
qp 1.5 m³/h => 10 K > 150l /h
qp 2.5 m³/h => 5 K > 250 l/h
4.1 Installation in the ball valve with adapter
(coupling set in a separate bag)
Use ball valves with installation option for temperature sensor with thread
M10 x 1.
Preparatory measures
Close the ball valve.
Unscrew the plug screw from the ball valve.
Installation (see fig. II)
1. Place the O-ring from the attached coupling set (type A or B) on the
mounting pin.
2. Insert the O-ring with the mounting pin into the sensor hole of the ball
valve (turn the mounting pin).
3. Position the O-ring in its final position using the other end of the
mounting pin.
-9- English Italiano Dansk Svenska
4. Fastening screws
Type A (plastic) - plug the fastening screw onto the temperature sensor.
Type B (brass) - insert the temperature sensor in the fastening screw
and place the sensor in the mounting pin. Press in the dowel pin com-
pletely and remove the mounting pin.
5. Insert the temperature sensor with the securing fitting in the ball
valve and manually tighten (2-3 Nm).
4.2 Installation in a pocket
It is recommended that temperature sensors for DN25 rated sizes or
smaller are only fitted in new installations such that they are directly
immersed.
This ensures higher measuring accuracy.
5. Start-up operation
Once the meter has been installed, the components (calculator, volume
measuring component and both temperature sensors) must be sealed
with a tamper-proof seal and the meter started up by a specialist com-
pany approved according to the legislation.
QUALITY
CERTIFIED
C
E
Q
U
A
L
I
T
Y
QUALITY CERTIFIED
Q
QUALITY
CERTIFIED
-10- English Italiano Dansk Svenska
Check the display for a plausible indication of flow rate and temper -
atures.
User guide for further Information is available at
https://www.diehl.com/metering/en/support-center/download-center/
5.1 Inlet / outlet setting (optional ex works)
Optionally, the installation position of the meter can be set in-situ in loop 3
("3.4" on page 14 ). Consequently installation in the inlet (flow) or outlet
(return) is possible.
This setting must be made prior to initial operation of the meter.
As supplied, the outlet (return) is pre-set and is shown as follows in the
display.
Setting and number of possi-
ble changes.
To changeover, switch to the "Outlet" window in loop 3 (see "8. Opera-
tion" on page 14).
Pressing and holding the button for > 6 s changes the display/setting to
"Inlet".
This setting can be changed a total of 8 times by pressing the button.
The display changes during the 6 s.
This does not influence functioning.
-11- English Italiano Dansk Svenska
Sequence during changing
Button pressed <3s Button pressed >3s
If the button is pressed and then held for > 6 s, the meter performs the
command shown in the display.
In each change, the framed
number in the display is
reduced by 1.
After 8 changes, it is no longer possible to change the installation position.
The possibility of changing lapses either immediately upon
detection of water, or after three hours’ operation without error
detection (pre-set ex works).
The following indication appears in the display (example):
The changes indication dis-
appears.
When changing the installation position, the sensors must be
matched to the actual installation (see "4. Temperature sensor"
on page 8).
-12- English Italiano Dansk Svenska
6. Communication
Communication modules must be secured so that opening of
meters is only possible by destroying the securing points.
The calculator supports two communication channels (radio (wireless) or M-Bus).
The protocols may be different for all two communication channels and
are pre-set ex works. The telegrams can be defined for each customer
using the IZAR@MOBILE 2 software.
6.1 Communication via radio
The integrated radio module is an interface for communication with Diehl
Metering radio receivers.
Unidirectional communication has the following specification:
The module transmits every 8 ... 256 s (send period max. 0.1 %
of duty cycle (min. 8s); variable, depending on protocol length and
programming)
The communication always transfers the currently measured data
Transmission frequencies:
– 434 MHz, transmission power (EN 300 220-2 V3.2.1): 10mW e.r.p.
– 868 MHz, transmission power (EN 300 220-2 V3.2.1): 25mW e.r.p.
Various Diehl Metering receivers are available for receiving the proto-
col (e.g. Bluetooth, GPRS, LAN, …)
The protocol corresponds to OMS Profile A or Profile B and is
encrypted.
Reading modes: Walk-By, Drive-By, Fixed-Network
For problematic radio installations (shield) the external wireless mod-
ule set can also be used
6.2 M-Bus Communication module
The M-Bus communication module is a serial interface for communication
with external devices (M-Bus control centres), e.g. IZAR CENTER. A num-
ber of meters can be connected to a control centre.
The connection is not polarity-sensitive and is electrically isolated
M-Bus protocol standardised according to EN 1434;
300 or 2400 baud (auto baud detect)
Connection for 2 x 2.5 mm²;
Power consumption: One M-Bus load
-13- English Italiano Dansk Svenska
7. Display
The data generated by the calculator can be viewed in several displays. These
displays contain the assigned system information (e.g. energy quantities,
water volumes, operating days, water quantities, actual temperatures, max-
imum values) and can be accessed by calling the displays in